19+ years experience in power transmission & distribution equipment manufacturing, one-stop solution provider for electrical equipment.
Product details
CCX-8/M intelligent intensive busway is a utility & high-tech busway product,It is saving project construction fees and user fees Comparing to the traditional busway,.And the social economic benefits are very considerable. The development results can meet the requirement of national reform which will be replaced the traditional. The improvement of energy efficiency is crucial to the transformation of our country into an energy-saving society.
The housing of busway is used in high quality none magnetic alloy material which does not produce outward electromagnetic wave radiation in the process of electric energy transmission and can greatly reduce the line loss,That would be saved energy and reduce electromagnetic radiation pollution.
In addition, the product is specially equipped with a radiator and increase the heat dissipation area of the conductive bar, Accelerating its heat dissipation can greatly reduce the temperature rise and reduce the electric field strength of the conductor surface, avoiding corona discharge and reduce power transmission loss. For radio interference, this busway can increase the power saving rate effectively of more than 15%, so that it would be alleviate the shortage of power energy.
Product parameter
Specifications | IEC60439-1:1999、GB7251.1-2005 IEC60439-2:2000、GB7251.2-2006、JB/T9662-2011 |
(KA) Rated short-time withsatand current |
20 | 30 | 50 | 65 | 100 | ||||||||||||||||||||
Ambient temperature | -15/+40 | (KA)Rated peak current | 42 | 63 | 105 | 176 | 220 | ||||||||||||||||||||
Height above sea level | not exceeding 2000m | Temperature rise test(℃) | ≤40 | ≤40 | ≤45 | ≤45 | ≤50 | ||||||||||||||||||||
Degree of protection | lp66 | Insulation(MΩ) | ≥200 | ||||||||||||||||||||||||
Unit Length(m) | ≤9 | Cleaeance(mm) | ≥10 | ||||||||||||||||||||||||
UiRated insulation Voltage (V) | 690/1000 | Clearance(mm) | ≥12.5 | ||||||||||||||||||||||||
UeRated aperational Voltage(V) | 380/660 | PE(Ω)Creepage distance | <0.01 | ||||||||||||||||||||||||
Frequence(HZ) | 50(60) | Power withstand voltage | 10KV/1min No breakdown,No flashover |
||||||||||||||||||||||||
Rated current(A) | 400 | 500 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 4000 | 5000 | 6300 | 8000 | Mounting | Vertical or horizontal | ||||||||||||
Resistance R20(uΩ/m) | 91.5 |
84.5 |
73.5 |
59.74 |
48.9 |
38.3 |
28.8 |
25.4 |
20.6 |
10.5 |
6.8 |
5.8 |
5.3 |
Tap-off unit amount | minimum 0.6/unit | ||||||||||||
Resistance X20(uΩ/m) | 25.6 | 24.3 | 23.6 | 19.4 | 23.5 | 13.1 | 15.9 | 13.8 | 11.1 | 7.8 | 6.4 | 7.5 | 6.8 | Fixing intervals(m) | 3 | 2 | |||||||||||
Total Impedance Z20(uΩ/m) | 85.2 |
80.2 |
77.2 |
62.7 |
54.2 |
40.5 |
32.9 |
28.9 |
23.4 |
13.5 |
11.5 |
12.3 |
10.8 |
For balanced load(kg/m) | 15 | 20 | 40 | 60 | 70 | ||||||||
Voltage drop(V/m) (COSΦ =0.9h) |
0.035 | 0.040 | 0.048 | 0.056 | 0.050 | 0.051 | 0.049 | 0.048 | 0.049 | 0.054 | 0.045 | 0.050 | 0.052 | For concentrated load(kg) | 80 | 110 | 140 | 150 | 200 |